Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9845889

- Product Categories
- Friendly Links
Information Name: | Supply voltage AC powered equipment |
Published: | 2013-10-20 |
Validity: | 30 |
Specifications: | cfxr |
Quantity: | 900.00 |
Price Description: | |
Detailed Product Description: | Soft starter electrical control cabinet CFXR-RQ soft-start control cabinet is mainly used for all kinds of high-power motor starting, the use of soft-start to replace the traditional way to start, to achieve a smooth start, starting current is reduced, reducing the motor starts, the larger current of the motor mechanical shock, and the impact on power, improve power quality and energy conservation. Stall protection and the use of fast protection against mechanical failure or stall blocked causing the motor to overheat and burn, reduce the voltage drop caused by large currents, affect other electrical appliances, reduce wear and extend motor life, saving machinery maintenance costs. 2, intelligent: the traditional soft starter set a time, starting voltage value command, no matter how light and heavy load, the procedure will be completed in accordance with the set time command to soft-start the process. The resulting light load of unnecessary equipment wear and tear, such as some low-voltage light load device does not allow time starter; while overloading caused by the accumulation of time when the soft starter component damage. DMR2 completely avoid the artificial defects, can be a way starter inductive load. Features Feature Name Description Setting range 30-70% starting voltage voltage ramp mode is active; Code FB set 1:00 to modify, FB O is set to 40% starting voltage soft start time 2-60S Voltage Ramp mode is active ; Code FB set 1:00 to modify soft stop time 0-60S set O is free parking, a drag N should be set to 0 start delay 0-999S press the start button to use (set time) countdown delay starting, immediately set 0 Start programming delay 0-999S run relay output (terminals 03 and 04), located between 0:00 start immediately release delay 0-999S when overheated delay, delay status indicator flashes during the prompt start to limit the current 50-500 % Current Limit mode is active; code set 0:00 modify FB Fb set a time limit for the effective flow of up to 400% of the maximum value of current 50-200% F6, F7 F8 parameters are determined by the keyboard input mode display current values ??00-03, the percentage of under- voltage protection 60-90% below the set value protection Overvoltage protection 100-130% higher than the set value protection starting mode 00-0500 limiting; 01 voltage; 02 jumps + limit; 03 jumps + voltage; 04 current ramp; 05 pairs of closed-loop output protection allows 00-0400 primary; 01 light load; 02 standard; 03 overloaded; 04 Advanced Control Control mode 00-07 set 0:00 to restart the keyboard allows 00-090 : Prohibition; 01-09: Automatic restart frequency parameter modification allows 00-0100: not allowed to modify the parameters; 01: Allows modifying parameters mailing address 00-64 soft starter for more than one multi-machine communication with the host computer programmed to output 00 -07 run relay output (terminals 03,04) Set Note: 1, the code F7 maximum operating current is allowed to set the FP motor is calculated based on the number of sustainable operation of the maximum current, the timeout value will do inverse thermal protection. Setting out two minutes if the state did not press the action button, it will automatically exit the setting mode. 3, in the soft starting and soft stopping process can not set parameters, other states may set parameters. Third, the classification of a soft start cabinet, according to the voltage: Low voltage soft start cabinet, high voltage soft starter cabinet 2, depending on the load: Fan soft start cabinet, pump soft starter cabinet, etc. 3, depending on the load control in different ways: a drag of a soft, more than a drag, one with a prepared, Uses a soft start cabinet, etc. |
Admin>>>
You are the 18153 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Chong Fook cutting-edge Electric Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 18153 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Chong Fook cutting-edge Electric Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility